TN1838 Blankets Flammability Tester
INTRODUCTION
To test blanket fabric flame retardant performance and fabric surface flame spread performance,
the test method is within the stipulated time, to standardize the flame was carried out on the
sample surface combustion, the combustion of standard test paper, to look at the degree of
damage or discoloration, and fabric for grading evaluation of the test.
TECHNICAL PARAMETERS
1.Test chamber : 37×22×35 cm, 12 ventilation holes of φ12.7 mm in the top
2.Standard flame height : 16 mm, adjustable,No.18 hypodermic needle
3.Ignition time : can be set freely, standard requirement of 1 s
4.Timing accuracy : 0.1 s
5.Flow meter range : 0~60 ml/min
6.Specimen size : 70 mm×70 mm
7.Specimen holder size : inner diameter of 63.5 mm
8.Dimension : 42×26×52 cm (L×W×H)
9.Weight : 20 kg
10.Power supply : AC220V,50/60 Hz, 3 A
STANDARDS
ASTM D4151